Product information
- Power supply to the control unit: ~ 110–230 V / 50–60 Hz, max. 0.85 A with fuse F1.6 A/250 V, safety class II
- Backup battery: 12V; 7 - 18 Ah (lead gel battery not included (Scope of delivery)
- BUS voltage (red - black): 12.0 to 13.8 V
- Maximum continuous current consumption from the control unit: 2000 mA permanently, 3000 mA for 60 minutes (max. 2000 mA for one BUS)
- Maximum continuous power consumption for a 12-hour backup. (without GSM dialer and transmission device): LAN – OFF: 1135 mA, LAN – ON: 1107 mA
- Maximum continuous power consumption for a 12-hour backup. (with GSM dialer and transmission device): LAN – OFF: 1100 mA, LAN – ON: 1072 mA
- Maximum continuous power consumption for a 24-hour backup (without GSM dialer and transmission device): LAN – OFF: 535 mA, LAN – ON: 499 mA
- Maximum continuous power consumption for a 24-hour backup (with GSM dialer and transmission device): LAN – OFF: 530 mA, LAN – ON: 494 mA
- Maximum number of peripheral devices: 230
- LAN communicator: Ethernet interface, 10/100BASE-T
- Dimensions (W x H x D): 357 x 297 x 105 mm
- Weight with/without battery: 7027 g/1809 g
- Response to an invalid code entry: Alarm after 10 incorrect code entries
- Event log: Approximately 7 million recent events, including date and time
- Note T 031: In the event of a power outage, the system will be down for 24 hours. Power supplied for hours and simultaneously a fault report sent to the control center sent.
- Classification: Safety class 2/Environmental class II (according to EN 50131-1)
- Operating environment: Environment class II (general) Indoor areas) according to EN 50131-1
- Operating temperature range: -10 °C to +40 °C
- Average operating humidity: 75% RH, not condensing
- Corresponds to: EN 50131-1 ed. 2+A1+A2, EN 50131-3, EN 50131-5-3+A1, EN 50131-6 ed. 2+A1, EN 50131-10, EN 50136-1, EN 50136-2, EN 50581
- Radio frequency (with the JA 11xR module): 868.1 MHz
- Radio emissions: ETSI: EN 300 220-1,-2 (Module R), ETSI EN 301 419-1, ETSI EN 301 511 (GSM), EMC: EN 50130-4 ed. 2+A1, EN 55032 ed. 2, ETSI EN 301 489-7
- Safety compliance: EN 62368-1+A11
- 1x Central unit JA-107KR
- 1x built-in radio module JA-111R
- 1x built-in LAN module
- Power supply to the control unit: ~ 110–230 V / 50–60 Hz, max. 0.85 A with fuse F1.6 A/250 V, safety class II
- Backup battery: 12V; 7 - 18 Ah (lead gel battery not included (Scope of delivery)
- BUS voltage (red - black): 12.0 to 13.8 V
- Maximum continuous current consumption from the control unit: 2000 mA permanently, 3000 mA for 60 minutes (max. 2000 mA for one BUS)
- Maximum continuous power consumption for a 12-hour backup. (without GSM dialer and transmission device): LAN – OFF: 1135 mA, LAN – ON: 1107 mA
- Maximum continuous power consumption for a 12-hour backup. (with GSM dialer and transmission device): LAN – OFF: 1100 mA, LAN – ON: 1072 mA
- Maximum continuous power consumption for a 24-hour backup (without GSM dialer and transmission device): LAN – OFF: 535 mA, LAN – ON: 499 mA
- Maximum continuous power consumption for a 24-hour backup (with GSM dialer and transmission device): LAN – OFF: 530 mA, LAN – ON: 494 mA
- Maximum number of peripheral devices: 230
- LAN communicator: Ethernet interface, 10/100BASE-T
- Dimensions (W x H x D): 357 x 297 x 105 mm
- Weight with/without battery: 7027 g/1809 g
- Response to an invalid code entry: Alarm after 10 incorrect code entries
- Event log: Approximately 7 million recent events, including date and time
- Note T 031: In the event of a power outage, the system will be down for 24 hours. Power supplied for hours and simultaneously a fault report sent to the control center sent.
- Classification: Safety class 2/Environmental class II (according to EN 50131-1)
- Operating environment: Environment class II (general) Indoor areas) according to EN 50131-1
- Operating temperature range: -10 °C to +40 °C
- Average operating humidity: 75% RH, not condensing
- Corresponds to: EN 50131-1 ed. 2+A1+A2, EN 50131-3, EN 50131-5-3+A1, EN 50131-6 ed. 2+A1, EN 50131-10, EN 50136-1, EN 50136-2, EN 50581
- Radio frequency (with the JA 11xR module): 868.1 MHz
- Radio emissions: ETSI: EN 300 220-1,-2 (Module R), ETSI EN 301 419-1, ETSI EN 301 511 (GSM), EMC: EN 50130-4 ed. 2+A1, EN 55032 ed. 2, ETSI EN 301 489-7
- Safety compliance: EN 62368-1+A11
- 1x Central unit JA-107KR
- 1x built-in radio module JA-111R
- 1x built-in LAN module
Jablotron central JA-107KR including LAN + radio module
- Regular price
- €813,90
- Sale price
- €813,90
- Regular price
-
€1.087,20
Couldn't load pickup availability
SKU: Product number: JA-107KR
Invoice without VAT
Business customers from Germany and other EU countries (excluding Austria) can have their goods invoiced without VAT. Simply provide your valid VAT identification number during the ordering process.
INFO: Sales tax will only be deducted at checkout.
Order with VAT identification number
The easiest way to enter your VAT ID number is during the customer account creation process: Click here

Alternatively, you can access the shopping cart during the ordering process (either on the side or directly on the shopping cart page). There, enter your valid VAT identification number in the "VAT ID" field; this will automatically process your order tax-free.

Special conditions for large orders
Please contact us for large orders. We will promptly provide you with a customized offer with special conditions.